Moxi2 receiver in canal (RIC) guideFPO
10Attaching the dome or sleeve mold to the standard xReceiver unit1. Hold the xReceiver unit in one hand and the coupling (i.e. dome or sleeve mold)
11Attaching the standard, power or super power xReceiver unit to Moxi2KissAttaching the xReceiver unit to Moxi2 Kiss1. Use the small silver tool t
12Attaching the standard, power or super power plus xReceiver unit to Moxi2 Dura Attaching the xReceiver unit to Moxi2 Dura1. Ensure the xReceiver l
13Conguring in Unitron TrueFit sowareDetection screen1. Connect hearing instrument to the NOAHLink, HI-PRO, or iCube and click the detect icon. U
14Feedback optimizationRun Feedback Optimization.AppendixUsing the Moxi2 shell removal toolThe shell removal tool is used to remove the top shell from
15Replacing the top shell1. Position the top shell over the push button on the hearing instrument.2. Then push the shell down and back until it s
16Moxi2 Kiss battery door replacementRemoval1. Use the small silver tool to push the pin out.2. Remove the battery door. Installation1. Line up
17Moxi2 battery door replacementRemoval1. Use the small silver tool to push the pin out.2. Remove the battery door. Installation1. Line up the batt
18Moxi2 Kiss programming cableInsertion1. Open the battery door to reveal the programming port.2. Push the cable down onto the programming port.Re
19Moxi2 programming cableInsertion(The optional programming tool can be used for support during the installation.)1. Place the optional programming
Table of Contents Unitron’s Moxi2 RIC product line Moxi2 KissAvailable RIC ttings Gain/peak output (2cc)BatteryStandard RICPower RICSuper power RIC45
Australia - 1800 212 313Belgium - +32 (0) 2 468 19 81Canada - 1 800 265 8255China - 512 6258 2258Colombia - 57 1214 9847Denmark - +45 3832 1229Europea
3250 500 1000 2000 4000 8000 -100102030405060708090100110120Hz250 500 1000 2000 4000 8000 -100102030405060708090100110120HzPower dome Power domeSleeve
4To measure for an accurate wire length:1. Place your head at the same horizontal level as the patient’s head so you are looking straight into the
5Modifying xReceiver wire to improve tIn some cases, you might nd that the wire of the xReceiver unit does not lie close to the side of the head or
6Choosing the correct coupling for standard xReceiversDetermine the correct dome size based on your otoscopic examination of the ear canal. Selectthe
7Choosing the correct coupling for power xReceiversDetermine the correct dome size based on your otoscopic examination of the ear canal. Selectthedo
8Choosing the correct coupling for super power and super power plus xReceiversSelect,basedon the audiometric requirements and tting ranges shown o
9Attaching the retention piece tothe standard or power xReceiver unitThe retention piece may be used for ttings with the open or closed dome dependi