Unitron Yuu User Manual

Browse online or download User Manual for Headphones Unitron Yuu. Yuu program gd,x-default

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Table of Contents
Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . 2
Status Bar . . . . . . . . . . . . . . . . . . . . . . . 2
FastTrack
by U:fit . . . . . . . . . . . . . . . . 3
FastTrack
Client Screen . . . . . . . . . . . 3
FastTrack
Instruments Screen . . . . . . 3
FastTrack
Setup Screen . . . . . . . . . . . 4
FastTrack
Acoustics Screen . . . . . . . . 5
FastTrack
Feedback Optimization
Screen . . . . . . . . . . . . . . . . . . . . . . . 5
FastTrack
Fitting Screen. . . . . . . . . . . 5
FastTrack
Fine Tuning Screen . . . . . . 6
FastTrack
Fitting Advice Screen . . . . 7
FastTrack
End Fitting Screen . . . . . . . 7
Client Screen . . . . . . . . . . . . . . . . . . . . . 8
Hearing Loss Simulator Screen . . . . . . 9
In Situ Screen . . . . . . . . . . . . . . . . . . . . 9
ABR Screen . . . . . . . . . . . . . . . . . . . . . . 9
COSI Screen. . . . . . . . . . . . . . . . . . . . . 10
Instruments Screen . . . . . . . . . . . . . . 11
Setup Screen . . . . . . . . . . . . . . . . . . . . 11
Acoustics Screen. . . . . . . . . . . . . . . . . 13
Pre-Fitting Screen . . . . . . . . . . . . . . . . 13
Feedback Optimization Screen . . . . . 14
Quick Tuning Screen . . . . . . . . . . . . . 15
Configure Screen . . . . . . . . . . . . . . . . 16
Fine Tuning Screen . . . . . . . . . . . . . . . 17
AutoPro4
Controls Screen . . . . . . . . 18
Fitting Advice Screen . . . . . . . . . . . . . 18
Data Logging Screen . . . . . . . . . . . . . 18
Volume Control Screen. . . . . . . . . . . . 19
SmartFocus
Screen . . . . . . . . . . . . . . 19
End Fitting Screen . . . . . . . . . . . . . . . 20
Passport
Programming Guide
Getting ready to program BTE hearing instruments:
BTE hearing devices are Quick Fit to a 50 dB flat hearing loss
Remove battery during programming
Open programming port cover and insert programming cable
Connect other end of the cable to the HI-PRO box or NOAHlink
Program button, volume control, smartFocus
, Smart Control, easy-t, easy-DAI,
and automatic microphone options are deactivated during programming.
Getting ready to program custom hearing instruments:
Custom hearing devices are Quick Fit if an audiogram is supplied
Remove battery door and insert appropriate right or left cable
Connect other end of the cable to the Hi-Pro box or NOAHlink
Program button, volume control, smartFocus, Smart Control, easy-t, and
automatic microphone options are deactivated during programming.
Ear HookDual Directional
Microphones
Push Button Volume
Control or Program
Button (depending on
customized fitting)
Battery Door
Volume Control or
smartFocus (depending
on customized fitting)
Microphone Protection
Programming Port Cover
Battery Door
Push Button Volume Control or
Program Button (depending on
customized fitting)
Dual Directional
Microphones
Volume Control or
smartFocus (depending
on customized fitting)
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1

Table of ContentsToolbar . . . . . . . . . . . . . . . . . . . . . . . . . 2Status Bar . . . . . . . . . . . . . . . . . . . . . . . 2FastTrack™by U:f

Page 2 - Status Bar

Passport™Programming Guide10COSI ScreenTo complete the Client Oriented Scale ofImprovement (COSI) form at your client’s initialappointment:1. Click th

Page 3

Passport™Programming Guide11Instruments ScreenOnce the client’s information and audiometric data has been entered, the next step isto either detect th

Page 4 - FastTrack

Passport™Programming Guide12To pair Smart Control:1. Enter the Smart Control serial number into the empty field.Note: The serial number is for referen

Page 5

Passport™Programming Guide13Acoustics ScreenClick Acoustics or for venting, slim tube,xReceiver unit, and coupling choices.• For Moda™II and Moda™13,

Page 6 - Fine Tuning

Passport™Programming Guide14RECD and REUGTo complete the RECD and REUG screens, enter the audiometric data by clicking on thegraph or by using the tab

Page 7

Passport™Programming Guide15Quick Tuning ScreenNote: Within the Quick Tuning screen, both ears arelinked. To unlink the two ears, click the Link/Unlin

Page 8 - Client Screen

Passport™Programming Guide16Configure ScreenIn the Configure screen, you may review/modifyautoPro4 destinations and/or manual programs.These settings

Page 9

Passport™Programming Guide17Fine Tuning ScreenTo fine tune the hearing instrument:1. Select the program you wish to fine tune: AllPrograms, All AutoPr

Page 10 - COSI Screen

Passport™Programming Guide18AutoPro4™Controls ScreenSensitivity Control:The Sensitivity Control determines how autoPro4responds to changes in the envi

Page 11 - Setup Screen

Passport™Programming Guide19the hearing device before new settings are saved to the hearing device.Understanding the Data Logging Information:The top

Page 12

Passport™Programming Guide2Programming with iCube:•Insert appropriate size battery• Place instrument(s) inside iCube neck loopWhen you are ready to pr

Page 13 - Pre-Fitting Screen

Passport™Programming Guide20End Fitting Screen1. Use the controls to adjust the Beep Frequency(Very Low, Low, Mid, High)and Beep Intensity(Very Soft,

Page 14 - Feedback Optimization

Passport™Programming Guide3FastTrack™by U:fitSelect fastTrack from the toolbar.The may be used to turn fastTrack ON/OFF at anytime during the fitting.

Page 15 - Quick Tuning Screen

Passport™Programming Guide4To simulate a hearing device fitting:1. Click on the down arrows.2. Select the desired product, shell style, ear(s), andmod

Page 16 - Configure Screen

Passport™Programming Guide5FastTrack™AcousticsScreenThe Acoustics screen is for selecting venting, slimtube, xReceiver unit and coupling choices.For M

Page 17 - Fine Tuning Screen

Passport™Programming Guide6FastTrack™Fine TuningScreenTo fine tune the hearing instrument:1. Select the program you wish to fine tune.The Basic view g

Page 18

Passport™Programming Guide7FastTrack™Fitting AdviceScreen1. Select All Programs, All AutoPro4 or individualprogram.2. Select the situation which best

Page 19 - SmartFocus

Passport™Programming Guide8Client ScreenWhen running U:fit under NOAH, the Client screen isfor reference only. When using the U:fit standaloneversion,

Page 20 - End Fitting Screen

Passport™Programming Guide9Hearing Loss SimulatorScreenThe Hearing Loss Simulator allows you todemonstrate the impact of a hearing loss by playingsoun